- Plus and minus side overload proof up to rated pressure
- Measuring cell is vacuum proof
- Index scale to enable re-setting to a previously set span
- Zero elevation and suppression facilities can also be fitted
later
- Signal reversal declining characteristic by suppression of zero and
interchanging the plus and minus connections at the transmitter
- Parts in contact with process medium made of Mat. No. 1.4571, optionally of special
materials
- Versions for O2, H2, NH3 service
- Process temperature from 40 °C to +125 °C
(40 °F to +257 °F)
|
Conversion of
mechanical quantities into the 0.2 to 1 bar, 3 to 10 psi or 20 to 100 kPa standard
pneumatic signal for flow of liquids, vapors and gases, differential pressure and liquid
levels.
Also suitable for aggressive and corrosive process media.
|